| AC Rating: |
10 amps at 115 vac (Resistive load)
5 amps at 115 vac (Inductive load)
3 amps at 115 vac (Lamp load) |
| DC Rating: |
10 amps at 28 vdc (Resistive load)
5 amps at 28 vdc (Inductive load)
3 amps at 28 vdc (Lamp load) |
Type 7 Contact
Configuration: |
Ratings are ONE HALF amperage
loads shown above. |
| Mechanical Life: |
500,000 cycles |
| Action: |
Momentary Snap or Push-Pull (as specified) |
| Plunger Travel: |
.085" +/- .015" |
Series 20 & 30
Operating Force: |
3 to 5 pounds momentary
1/2 to 2 pounds push-pull |
Series 22 & 32
Operating Force: |
2 to 3 pounds |
| Weight: |
.050 pound maximum |
Case and
Adapter: |
Aluminum alloy, 2011-T3, anodized
in accordance with MIL-A-8625 |
Plunger and
Button: |
Glass-filled nylon or nylon in accordance with
ASTM D4066 |
| Body Insulation |
Diallyl phthaliate in accordance with MIL-M-14 |
| Terminals: |
Threaded 2-56 NC-2B for use with hardware
or solder type connection |
| Terminal Hardware: |
Solder-type wire terminals, with terminal mounting
screws and lockwashers, supplied with each switch. |
| Mounting: |
Switch with mounting adapters
C,F,G or H supplied with a 5/8"-24 UNEF-2B nut
and internal tooth lockwasher.
Basic 200 Series and 300 Series switches
supplied with a 1/2"-32 UNEF-2B nut
and internal tooth lockwasher.
|
| Special: |
Additional types of mounting, button styles, colors, and
other variations are available on special order
|